| MALFUNCTION |
POSSIBLE CAUSE |
REMEDY |
|
| STROKE OR CAPACITY
INCREASE |
1. REACTOR SPRING BREAKAGE. |
REPLACE SPRINGS. |
| |
2. REACTOR SPRING LOOSE. |
TIGHTEN BOLTS PER THE
TORQUE CHART IN MANUAL. |
| |
3. MATERIAL BUILD-UP. |
CLEAN TROUGH. |
| |
4. ADDITIONAL TROUGH
WEIGHT. |
CONTACT GENERAL KINEMATICS'
ENGINEERING DEPARTMENT |
|
| STROKE DECREASE |
1. MATERIAL BUILD-UP. |
CLEAN TROUGH. |
| |
2. TROUGH HITTING STATIONARY
EQUIPMENT. |
CHECK CLEARANCE ON
THE GENERAL KINEMATICS ARRANGEMENT DRAWINGS. |
| |
3. "V-F" COUNTERWEIGHT
WHEEL BAD or *(LOST or LOW PRESSURE). |
REPLACE BOTH "V-F" WHEELS,
CHECK AIR/HYD LINE. |
*MAXIMUM FEED RATE PRESSURE MAY VARY DEPENDING ON
DESIGN - REFER TO THE GENERAL ARRANGEMENT DRAWING/S. |
| IMPROPER MATERIAL PROCESSING. |
1. ROCKER LEG FAILURE . |
REPLACE ROCKER LEG. |
| |
2. ISOLATION SPRING
BREAKAGE. |
REPLACE ISOLATION SPRING. |
| |
3. MATERIAL BUILD-UP. |
CLEAN OUT. |
| |
4. LOOSE BOLTS. |
TIGHTEN BOLTS TO PROPER
TORQUE. |
|
| MATERIAL NOT CONVEYING
or LOW CAPACITY |
1. GATE CLOSED |
OPEN GATE. |
| |
2. OBSTRUCTION IN TROUGH. |
REMOVE OBSTRUCTION. |
| |
3. "V-F" WHEELS BAD. |
REPLACE BOTH WHEELS. |
| |
4. *NO PRESSURE FOR ADJUSTABLE
FEEDER WITH 80 PSI MAX FEED RATE. |
CHECK AIR SUPPLY AND AIR LINES. |
*MAXIMUM FEED RATE PRESSURE MAY VARY DEPENDING ON
DESIGN - REFER TO THE GENERAL KINEMATICS ARRANGEMENT DRAWING/S. |
| NOISE |
1. LOOSE BOLTS. |
TIGHTEN BOLTS TO PROPER TORQUE. |
| |
2. BROKEN or LOOSE
SPRING. |
REPLACE BROKEN SPRING. |
| |
3. BROKEN OR LOOSE
ROCKER LEG |
REPLACE ROCKER LEG,
TIGHTEN BOLTS TO PROPER TORQUE. |
| |
4. HITTING STATIONARY
SKIRT. |
PROVIDE NECESSARY CLEARANCE. |
| |
5. WELD BREAKAGE. |
CONTACT GENERAL KINEMATICS' ENGINEERING
DEPARTMENT. |
|
| ROCKER LEG FAILURE |
1. LOOSE BOLTS. |
TIGHTEN BOLTS TO PROPER TORQUE
VALUE PER THE TORQUE CHART IN YOUR MANUAL. |
| |
2. BUSHING FAILURE. |
REPLACE RUBBER BUSHING. |
| |
3. MATERIAL BUILD-UP. |
CLEAN UP. |
|
| SPRING FAILURE |
1. LOOSE BOLTS. |
TIGHTEN BOLTS TO PROPER
TORQUE VALUE. |
| |
2. FATIGUE OR BROKEN. |
REPLACE SPRING. |
|
| MOTOR MALFUNCTION |
1. IMPROPER VOLTAGE. |
CHECK GENERAL ARRANGEMENT
DRAWING FOR PROPER VOLTAGE. |
| |
2. DISCONNECT OR STARTER. |
RESET, CHECK OVERLOAD
HEATER SIZE. |
| |
3. SINGLE PHASING. |
CHECK CABLE, WIRE LEAD,
& CABLE CONNECTION (MOTOR CONDUIT BOX IS PACKED WITH DUXSEAL
AND MUST BE REPACKED WITH SAME).. |
|